Particle therapy facilities in clinical operation
Information about technical equipment (last update: June 2024).
COUNTRY
|
WHO, WHERE
|
PARTICLE
|
S/C/SC*
MAX. ENERGY (MeV) |
BEAM DIRECTIONS
|
START
OF TREATMENT |
Austria
|
p
|
S 253
|
2 horiz., 1 vertical fixed beam**,
1 gantry** (under construction) |
2016
|
|
Austria
|
C-ion
|
S 403/u
|
2 horiz. and 1 verticalfixed beam**
|
2019
|
|
Belgium
|
p
|
SC 235
|
1 gantry**, 1 horiz. fixed beam
|
2020
|
|
China
|
WPTC, Wanjie, Zi-Bo
|
p
|
C 230
|
2 gantries, 1 fixed beam
|
2004
|
China
|
p
|
S 250
|
3 fixed beams**
|
2014
|
|
China
|
C-ion
|
S 430/u
|
3 fixed beams**
|
2014
|
|
China
|
C-ion
|
S 400/u
|
4 fixed beams**
|
2019
|
|
China
|
p
|
S 250
|
1 gantry**, 2 horiz. fixed beams**
|
2021
|
|
China
|
p
|
C 250
|
3 gantries**, 1 horiz. fixed beam**
|
2022
|
|
China
|
p
|
S 220
|
2 gantries**
|
2023
|
|
China
|
p
|
C 250
|
3 gantries**, 1 horiz. fixed beam**
|
2023
|
|
Czech Republic
|
p
|
C 230
|
3 gantries**, 1 fixed beam
|
2012
|
|
Denmark
|
p
|
C 250
|
3 gantries**, 1 horiz. fixed beam**
|
2019
|
|
France
|
p
|
C65, SC 235
|
1 fixed beam, 1 gantry**
|
1991, 2016
|
|
France
|
p
|
SC 230
|
1 gantry**, 2 fixed beams
|
1991, 2014
|
|
France
|
p
|
SC 230
|
1 gantry**
|
2018
|
|
Germany
|
p
|
C 72
|
1 fixed beam
|
1998
|
|
Germany
|
p
|
S 250
|
2 fixed beams, 1 gantry**
|
2009, 2012
|
|
Germany
|
C-ion
|
S 430/u
|
2 fixed beams, 1 gantry**
|
2009, 2012
|
|
Germany
|
p
|
C 230
|
4 gantries***, 1 fixed beam
|
2013
|
|
Germany
|
p | C 230 | 1 gantry*** | 2014 | |
Germany
|
p
|
S 250
|
3 horiz., 1 45deg. fixed beams**
|
2015
|
|
Germany
|
C-ion
|
S 430/u
|
3 horiz., 1 45deg. fixed beams**
|
2015
|
|
India
|
p
|
C 230
|
2 gantries, 1 fixed beam**
|
2019
|
|
India
|
p
|
C 230
|
3 gantries**
|
2023
|
|
Italy
|
p
|
C 60
|
1 fixe beam
|
2002
|
|
Italy
|
p
|
S 250
|
3 horiz., 1 vertical, fixed beams
|
2011
|
|
Italy
|
C-ion
|
S 480/u
|
3 horiz., 1 vertical, fixed beams
|
2012
|
|
Italy
|
p
|
C 230
|
2 gantries**, 1 fixed beams
|
2014
|
|
Italy
|
p
|
SC 230
|
1 gantry**
|
2023
|
|
Japan
|
C-ion
|
S 800/u
|
horiz.***, vertical***, fixed beams, 1 gantry
|
1994, 2017
|
|
Japan
|
p
|
C 235
|
2 gantries***
|
1998
|
|
Japan
|
p
|
S 230
|
1 gantry
|
2001
|
|
Japan | HIBMC, Hyogo |
C-ion
|
S 320/u
|
horiz.,vertical, fixed beams
|
2002
|
Japan | PMRC 2, Tsukuba |
p
|
S 250
|
2 gantries***
|
2001
|
Japan | Shizuoka Cancer Center |
p
|
S 235
|
3 gantries, 1 fixed beam
|
2003
|
Japan | STPTC, Koriyama-City |
p
|
S 235
|
2 gantries**, 1 fixed beam
|
2008
|
Japan
|
C-ion
|
S 400/u
|
3 horiz., 1 vertical, fixed beams
|
2010
|
|
Japan | MPTRC, Ibusuki |
p
|
S 250
|
3 gantries***
|
2011
|
Japan | Fukui Prefectural Hospital PTC, Fukui City |
p
|
S 235
|
2 gantries***, 1 fixed beam
|
2011
|
Japan | Nagoya PTC, Nagoya City, Aichi |
p
|
S 250
|
2 gantries***, 1 fixed beam
|
2013
|
Japan | SAGA-HIMAT, Tosu |
C-ion
|
S 400/u
|
3 horiz., vertical, 45 deg., fixed beams
|
2013
|
Japan | Hokkaido Univ. Hospital PBTC, Hokkaido |
p
|
S 220
|
1 gantry
|
2014
|
Japan | Aizawa Hospital PTC, Nagano |
p
|
C 235
|
1 gantry
|
2014
|
Japan | i-Rock Kanagawa Cancer Center, Yokohama |
C-ion
|
S 430/u
|
4 horiz., 2 vertical, fixed beams
|
2015
|
Japan | Tsuyama Chuo Hospital, Okayama |
p
|
S 235
|
1 gantry
|
2016
|
Japan | PTC Teishinkai Hospital, Sapporo, Hokkaido |
p
|
S 230
|
1 gantry
|
2016
|
Japan | Hakuhokai Group Osaka PT Clinic, Osaka |
p
|
S 235
|
1 gantry**
|
2017
|
Japan | Kobe Proton Center, Kobe |
p
|
S 235
|
1 gantry**
|
2017
|
Japan | Narita Memorial Proton Center, Toyohgashi |
p
|
C 230
|
1 gantry**
|
2018
|
Japan | Osaka Heavy Ion Therapy Center, Osaka |
C-ion
|
S 430/u
|
3 fixed beams, 6 ports**
|
2018
|
Japan | Hokkaido Ohno Memorial Hospital, Sapporo |
p
|
C 235
|
1 gantry**
|
2018
|
Japan | Takai Hospital, Tenri City |
p
|
C 230
|
1 gantry**
|
2018
|
Japan | Nagamori Memorial Center of Innovative Cancer Therapy and Research, Kyoto |
p
|
S 220
|
2 gantries**
|
2019
|
Japan | East Japan HIC,Yamagata University Hospital, Yamagata |
C-ion
|
S 430/u
|
1 SC gantry**, 1 horiz. & vertical fixed beam
|
2021
|
Japan | Shonan Kamakura Advanced Medical Center, Kanagawa |
p
|
S 220
|
1 gantry**
|
2022
|
Poland | IFJ PAN, Krakow |
p
|
C 230
|
1 fixed beam, 2 gantries
|
2011, 2016
|
Russia
|
p
|
S 250
|
1 fixed beam
|
1969
|
|
Russia
|
p
|
C 200****
|
1 fixed beam
|
1999
|
|
Russia
|
p
|
C 250
|
2 gantries**
|
2018
|
|
Russia
|
p
|
S 250
|
1 fixed beam
|
2016
|
|
Russia
|
p
|
C 230
|
4 gantries**
|
2019
|
|
Saudi Arabia | Saudi Proton Therapy Center, Riyadh | p |
C 250
|
3 gantries**, 2 fixed beams**
|
2023
|
Singapore | Mount Elizabeth Novena Hospital Proton Center | p |
C 230
|
1 gantry**
|
2023
|
Singapore | National Cancer Center Singapore (NCCS) | p |
S 250
|
4 gantries**, 1horiz. fixed beam
|
2023
|
Singapore | Singapore Institute for Advanced Medicine | p |
SC 250
|
1 gantry**
|
2023
|
South Korea | KNCC, IIsan |
p
|
C 230
|
2 gantrie, 1 horiz. fixed beam***
|
2007
|
South Korea | Samsung PTC, Seoul |
p
|
C 230
|
2 gantries**
|
2015
|
South Korea | Yonsei University Severance Hospital, Seoul |
C-iom
|
S 430/u
|
2 gantries, 1 horiz fixed beam**
|
2023
|
Spain
|
p
|
S 220
|
1 gantry**
|
2020
|
|
Sweden
|
p
|
C 230
|
2 gantries**
|
2015
|
|
Switzerland
|
p
|
C 250
|
3 gantries**, 1 horiz. fixed beam
|
1984, 1996, 2013, 2018
|
|
Thailand
|
p
|
C 250
|
1 gantry**
|
2021
|
|
Taiwan (China)
|
p
|
C 230
|
4 gantries**, 1 fixed beam exp.
|
2015
|
|
Taiwan (China)
|
p
|
C 230
|
3 gantries**.
|
2018
|
|
Taiwan (China)
|
p
|
C 230
|
1 gantry**.
|
2022
|
|
Taiwan (China)
|
C-ion
|
S 430/u
|
2 vertical & 2 horiz. fixed beams**.
|
2022
|
|
Taiwan (China)
|
p
|
C 250
|
2 gantries**.
|
2024
|
|
The Netherlands
|
p
|
C 230
|
2 gantries***
|
2018
|
|
The Netherlands
|
p
|
C 250
|
2 gantries**, 1 horiz. fixed beam**
|
2018
|
|
The Netherlands
|
p
|
SC 250
|
1 gantry**
|
2019
|
|
United Kingdom
|
p
|
C 62
|
1 fixed beam
|
1989
|
|
United Kingdom
|
p
|
C 230
|
1 gantry**
|
2018
|
|
United Kingdom
|
p
|
C 250
|
3 gantries**
|
2018
|
|
United Kingdom
|
p
|
C 230
|
1 gantry**
|
2019
|
|
United Kingdom
|
p
|
C 230
|
1 gantry**
|
2019
|
|
United Kingdom
|
p
|
C 250
|
3 gantries**
|
2021
|
|
USA, CA.
|
p
|
S 250
|
3 gantries, 1 horiz. fixed beam
|
1990
|
|
USA, CA.
|
p
|
C 60
|
1 horiz. fixed beam
|
1994
|
|
USA, MA.
|
p
|
C 235
|
2 gantries***, 1 horiz. fixed beam
|
2001
|
|
USA, TX. | MD Anderson Cancer Center, Houston |
p
|
S 250
|
3 gantries***, 1 horiz. fixed beam
|
2006
|
USA, FL. | UFHPTI, Jacksonville |
p
|
C 230
|
4 gantries***, 1 fixed beam
|
2006
|
USA, OK. | Oklahoma Proton Center, Oklahoma City |
p
|
C 230
|
1 gantry, 3 fixed beams
|
2009
|
USA, PA. | Roberts PTC,UPenn, Philadelphia |
p
|
C 230
|
4 gantries***, 1 horiz. fixed beam
|
2010
|
USA, IL. | Northwestern Medicine Proton Center, Warrenville |
p
|
C 230
|
1 gantry**, 3 fixed beams
|
2010
|
USA, VA. | HUPTI, Hampton |
p
|
C 230
|
4 gantries, 1horiz. fixed beam
|
2010
|
USA, NJ. | ProCure Proton Therapy Center, Somerset |
p
|
C 230
|
4 gantries***
|
2012
|
USA, WA. | Fred Hutchinson Cancer Center, Proton Therapy, Seattle |
p
|
C 230
|
4 gantries***
|
2013
|
USA, MO. | S. Lee Kling PTC, Barnes Jewish Hospital, St. Louis |
p
|
SC 250
|
1 gantry
|
2013
|
USA, TN. | Thompson Proton Center, Knoxville |
p
|
C 230
|
3 gantries**
|
2014
|
USA, CA. | California Protons Cancer Therapy Center, San Diego |
p
|
C 250
|
3 gantries**, 2 horiz. fixed beams**
|
2014
|
USA, LA. | Willis Knighton Proton Therapy Cancer Center, Shreveport |
p
|
C 230
|
1 gantry**
|
2014
|
USA, FL. | Ackerman Cancer Center, Jacksonville |
p
|
SC 250
|
1 gantry
|
2015
|
USA, MN. | Mayo Clinic Proton Beam Therapy Center, Rochester |
p
|
S 220
|
4 gantries**
|
2015
|
USA, NJ. | Laurie Proton Center of Robert Wood Johnson Univ. Hospital, New Brunswick |
p
|
SC 250
|
1 gantry
|
2015
|
USA, TX. | Texas Center for Proton Therapy, Irving |
p
|
C 230
|
2 gantries**, 1 horiz. fixed beam
|
2015
|
USA, TN. | St. Jude Red Frog Events Proton Therapy Center, Memphis |
p
|
S 220
|
2 gantries**, 1 horiz. fixed beam
|
2015
|
USA, AZ. | Mayo Clinic Proton Therapy Center, Phoenix |
p
|
S 220
|
4 gantries**
|
2016
|
USA, MD. | Maryland Proton Treatment Center, Baltimore |
p
|
C 250
|
4 gantries**, 1 horiz. fixed beam**
|
2016
|
USA, FL. | Orlando Health PTC, Orlando |
p
|
SC 250
|
1 gantry
|
2016
|
USA, OH. | UH Sideman CC, Cleveland |
p
|
SC 250
|
1 gantry
|
2016
|
USA, OH. | Cincinnati Children's Proton Therapy Center, Cincinnati |
p
|
C 250
|
3 gantries**
|
2016
|
USA, MI. | Beaumont Health Proton Therapy Center, Detroit |
p
|
C 230
|
1 gantry**
|
2017
|
USA, FL. | Baptist Hospital's Cancer Institute PTC, Miami |
p
|
C 230
|
3 gantries**
|
2017
|
USA, DC. | MedStar Georgetown University Hospital PTC, Washington DC |
p
|
SC 250
|
1 gantry**
|
2018
|
USA, TN. | Provision CARES Proton Therrapy Center, Nashville |
p
|
C 230
|
2 gantries**
|
2018
|
USA, GA. | Emory Proton Therapy Center, Atlanta |
p
|
C 250
|
3 gantries**, 2 horiz. fixed beams**
|
2018
|
USA, OK. | Stephensen Cancer Center, Oklahoma |
p
|
SC 250
|
1 gantry**
|
2018
|
USA, MI. | McLaren PTC, Flint |
p
|
S 250/330
|
3 gantries**
|
2019
|
USA, NY. | The New York Proton Center, East Harlem, New York |
p
|
C 250
|
3 gantries**, 1 horiz. fixed beam**
|
2019
|
USA, DC. | Johns Hopkins National Proton Center, Washington |
p
|
S 250
|
3 gantries**,1 horiz. fixed beam*
|
2019
|
USA, FL. | South Florida Proton Institute, SFPTI, Delray Beach |
p
|
C 250
|
1 gantry**
|
2019
|
USA, FL. | UFHPTI, Jacksonville |
p
|
C 230
|
1 gantry**
|
2019
|
USA, VA. | Inova Schar Cancer Institute PTC, Fairfax |
p
|
C 230
|
2 gantries**
|
2020
|
USA, FL. | UM Sylvester Dwoskin Proton Therapy Center, Miami |
p
|
C 250
|
1 gantry**
|
2020
|
USA, AL. | University of Alabama PTC, Birmingham |
p
|
C 250
|
1 gantry**
|
2020
|
USA, MA. | Gordon Browne Proton Center, MGH, Boston |
p
|
S 250
|
1 gantry**
|
2020
|
USA, UT. | Huntsman Cancer Institute, Salt Lake City |
p
|
S 250
|
1 gantry**
|
2021
|
USA, MO. | David C. Pratt CC, Mercy Hospital, St. Louis |
p
|
SC 250
|
1 gantry**
|
2022
|
USA, PA. | Penn Medicine Lancaster General Hospital Proton Center, Lancaster |
p
|
SC 250
|
1 gantry**
|
2022
|
USA, PA. | Penn Medicine Virtua Health, Proton Center, Southern NJ |
p
|
SC 250
|
1 gantry**
|
2023
|
USA, AR. | Kansas City Proton Institute (KCPI), Indian Creek |
p
|
SC 250
|
1 gantry**
|
2023
|
USA, AR. | UAMS Winthrop P. Rockefeller Cancer Institute, Little Rock |
p
|
SC 230
|
1 gantry**
|
2023
|
USA, OH. | The OSUCC Ohio State University Wexner Medical Center, Columbus |
p
|
SC 250
|
1 gantry**
|
2024
|
USA, IL. | OSF Health Care Cancer Institute, Peoria |
p
|
SC 250
|
1 gantry**
|
2024
|
USA, NC. | Atrium Health Levin Cancer, Charlotte |
p
|
SC 250
|
1 gantry**
|
2024
|
* S/C/SC = Synchrotron (S) or Cyclotron (C) or SynchroCyclotron (SC)
** with pencil beam scanning
*** with spread beam and pencil beam scanning
**** degraded beam
***** ? means: no confirmed information available about patient treatment